jenkins 3461a4e99d fix(ariadne): stop the kubelet killing a healthy triage pod
The liveness probe used the default timeoutSeconds of 1. The auto-triage tick
runs every minute and spends most of it waiting on Jenkins, OpenSearch, Gitea
and Hermes, so against a 500m CPU limit /health occasionally answers in over a
second. Three of those and the container is killed, dropping triage ticks for
the length of a restart. Observed 11 times in 139 minutes, with the pod
sitting 1/2 Ready and restarting repeatedly.

Give both probes a 5s timeout and let liveness tolerate five failures, so a
busy tick is no longer mistaken for a hung process.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-08-06 05:20:35 -03:00
..