monitoring: remove combined UPS draw series from history panels
This commit is contained in:
parent
411bc6b90d
commit
094d202803
@ -1318,11 +1318,6 @@
|
||||
"refId": "B",
|
||||
"expr": "((ananke_ups_load_percent{job=\"ananke-power\",source=\"Statera\"} * ananke_ups_power_nominal_watts{job=\"ananke-power\",source=\"Statera\"}) / 100)",
|
||||
"legendFormat": "Statera"
|
||||
},
|
||||
{
|
||||
"refId": "C",
|
||||
"expr": "sum((ananke_ups_load_percent{job=\"ananke-power\"} * ananke_ups_power_nominal_watts{job=\"ananke-power\"}) / 100)",
|
||||
"legendFormat": "combined"
|
||||
}
|
||||
],
|
||||
"fieldConfig": {
|
||||
|
||||
@ -245,11 +245,6 @@
|
||||
"refId": "B",
|
||||
"expr": "((ananke_ups_load_percent{job=\"ananke-power\",source=\"Statera\"} * ananke_ups_power_nominal_watts{job=\"ananke-power\",source=\"Statera\"}) / 100)",
|
||||
"legendFormat": "Statera"
|
||||
},
|
||||
{
|
||||
"refId": "C",
|
||||
"expr": "sum((ananke_ups_load_percent{job=\"ananke-power\"} * ananke_ups_power_nominal_watts{job=\"ananke-power\"}) / 100)",
|
||||
"legendFormat": "combined"
|
||||
}
|
||||
],
|
||||
"fieldConfig": {
|
||||
@ -267,7 +262,7 @@
|
||||
"mode": "multi"
|
||||
}
|
||||
},
|
||||
"description": "Historical UPS power consumption in watts for titan-db, tethys, and combined load."
|
||||
"description": "Historical UPS power consumption in watts for titan-db and tethys."
|
||||
},
|
||||
{
|
||||
"id": 3,
|
||||
|
||||
@ -1327,11 +1327,6 @@ data:
|
||||
"refId": "B",
|
||||
"expr": "((ananke_ups_load_percent{job=\"ananke-power\",source=\"Statera\"} * ananke_ups_power_nominal_watts{job=\"ananke-power\",source=\"Statera\"}) / 100)",
|
||||
"legendFormat": "Statera"
|
||||
},
|
||||
{
|
||||
"refId": "C",
|
||||
"expr": "sum((ananke_ups_load_percent{job=\"ananke-power\"} * ananke_ups_power_nominal_watts{job=\"ananke-power\"}) / 100)",
|
||||
"legendFormat": "combined"
|
||||
}
|
||||
],
|
||||
"fieldConfig": {
|
||||
|
||||
@ -254,11 +254,6 @@ data:
|
||||
"refId": "B",
|
||||
"expr": "((ananke_ups_load_percent{job=\"ananke-power\",source=\"Statera\"} * ananke_ups_power_nominal_watts{job=\"ananke-power\",source=\"Statera\"}) / 100)",
|
||||
"legendFormat": "Statera"
|
||||
},
|
||||
{
|
||||
"refId": "C",
|
||||
"expr": "sum((ananke_ups_load_percent{job=\"ananke-power\"} * ananke_ups_power_nominal_watts{job=\"ananke-power\"}) / 100)",
|
||||
"legendFormat": "combined"
|
||||
}
|
||||
],
|
||||
"fieldConfig": {
|
||||
@ -276,7 +271,7 @@ data:
|
||||
"mode": "multi"
|
||||
}
|
||||
},
|
||||
"description": "Historical UPS power consumption in watts for titan-db, tethys, and combined load."
|
||||
"description": "Historical UPS power consumption in watts for titan-db and tethys."
|
||||
},
|
||||
{
|
||||